NJCL Rapid concrete Chloride Content Tester tests the chloride content in concrete raw material to prevent construction rebar corrosion.
Feature: Large-size LCD panel to indicate data and an embedded printer to print data real-time in order to run independently without computer control. Software for testing and report preparation. Testing up to 6,9,12 cells simultaneously Documentation of each test result, easy to assemble, simple to maintain, watertight cells.
Technical Specification: Data storage :> 100 data PC communicates: baud rate 2400 Standby time :> 24 hr Work Temperature: 0 ºC ~ 40 ºC Range: 0.0001% ~ 30.00% (Cl ) or 10-5 ~ 10-1 M (mol • L-1)
Test Step: 1. Weigh sample, add distilled water or liquor 2. Calibrate electrode and test the sample solution 3. Print result (Printer shall be ordered separately)